Lance, leak
Service002 - lance, leak
Symptom:
The lance is spraying despite the feeding valve (R020j) is closed.
Reason:
The upper seal of piston in feeding valve is damaged. This happens mainly if it has not been smeared with silicone smear (Z05).
Solution:
Replace the seals or piston (alternatively whole valve R020j).
Smear with Marolex silicone smear Z05.
The silicone smear is available in the following kits: Z05, Z06, Z08j, Z08jV, Z08b, Tit37, Tit37v, Z08m
Concern series:
Profession, Hobby, Titan, Profession Plus, Industry, Auto - Washer, dis.Infector